Steps for Using a Membrane Switch
Release date:
2024-12-23
1. Clean the surface to be bonded with the film switch (the surface must be smooth, free of rust, oil, and dust).
2. Compare the size (Place the membrane switch at the intended pasting location to check if the size and position are accurate).
3. Next, peel off approximately 10 mm of the centrifugal paper from the edge at the bottom of the membrane switch.
4. Next, place the membrane switch onto the corresponding position and secure it partially. Then, slowly peel off the remaining release liner (while maintaining an angle no greater than 15 degrees), and carefully apply it sequentially to the designated areas.
5. During the pasting process, if the film switch on the reverse side of the centrifugal paper is removed, it should be placed temporarily with the reverse side facing upward to prevent sticking to other objects and affecting the adhesion.
6. Notes: Do not repeat the pasting process; complete it in one go. The tearing angle should not exceed 15 degrees. When testing the feel, ensure the film switch is placed flat on the table before pressing—do not press it while holding it in mid-air, as this may otherwise affect the lifespan of the membrane switch.